1014 PerformansUltra Flex Granite Adhesive
It is S2 Class very flexible, cement based adhesive mortar with high performance, reduced slip property, long working time.
► Cement Based
► Horizontal, Vertical Surfaces
► High Adhesion Strength
► Suitable for Heavy Pedestrian Traffic
► Very Flexible
► Low Consumption
> Grey / White
> Public Works Pos No: 04.013/1, 04.013/4
It gives excellent results;
• In horizontal and vertical applications in indoor and outdoor,
• Bonding of ceramic, granite, cotto, press brick, porcelain, glass mosaic, marble, natural and composite stones on all kinds of ground, (cement based surfaces, concrete, precast concrete elements, plaster, etc.)
• As an adhesive after priming of particleboard, OSB, PVC and metal floors (indoors only) with Termatect Plaster
• After priming the surfaces affected by temperature changes such as gypsum-plaster board, gypsum-plaster, heat-gas concrete with Termatect Plaster, bonding of ceramic on it,
• In wet areas such as swimming pools, water tanks, bathrooms, etc,
• Floor heating floors, heated pools, thermal pools, swimming pools where water is not drained in winter,
• Wall and floor coverings of cold storage depots,
• In ceramic and granite bonding works on the exteriors of buildings, renovation.
• High adhesion strength.
• Thanks to its S2 class flexibility, it is resistant to surface stresses caused by sudden heat changes.
• Resistant to all kinds of climatic conditions.
• Does not slip in vertical surface applications.
• It has long working time.
• Easy to comb.
a) Surface Preparation:
Take care that the application surface should be solid, dry, carrier, dust-free and clean and at the same time in balance. The surface should be thoroughly cleaned of all kinds of oil, grease, rust and paraffin residues that will weaken the adherence and there should be no loose particles on the surface. Damaged surfaces with a depth of 5 to 20 mm should be repaired with Termatect Repair Mortars two days in advance. If the temperature of the surface to be applied is above + 25°C, the surface should be moistened.
On Plaster Based Surfaces,
Termatect Plaster is applied on gypsum-paper board, gypsum-plaster, gas concrete, lime stuff and chipboard with high absorbency. Adhesion can be started 5 minutes after the primer application.
PVC Based Surfaces,
The existing PVC coating must be firmly adhered to the floor. All adherence reducing materials should be cleaned from the surface and the surface should be roughened with sandpaper and primed with Termatect Plaster.
On Metal Surfaces,
Interior metal surfaces (steel, aluminum, etc.) must be fixed in such a way that they do not move. The surface should be free of adherence reducing materials such as rust, dirt, dust and oil and primed with Termatect Primer.
Wood Particleboard Surfaces (OSB and Chipboards),
Wood particleboards should contain a maximum moisture content of 10%. Wood particleboard (V100) applied to the floors should be minimum 25 mm and 19 mm for the walls. The boards should be screwed to the surface at 30 cm intervals. The edge joint must be at least 8 mm wide. At the joints of the chips, grooves should be opened and filled with Joint Sealant. Wood paperboards should be primed with Termatect Plaster in dry environments. If the boards are in place that exposed to moisture (exterior), it is applied with Fully Flexible Waterproofing Material in two layers and mesh reinforced.
b) Product Preparation:
The water in appropriate amount is poured into the clean mixing vessel with a scale. 1014 Performans is added slowly and mixed with a 400-600 rpm mixer for 3-5 minutes until a uniform and lump-free mixture is obtained. After resting for 3-5 minutes and mixing again for 30 seconds, the material is ready for use.
c) Application Method:
1014 Performans layer of 1 mm thickness is applied to the application surface with the flat side of the trowel. 1014 Performans is applied in one direction in such a way that a uniform thickness is obtained with the toothed side of the trowel to an area that can be covered within 30 minutes, open waiting time. For the bonding of tiles or ceramics with different thicknesses, it is recommended to apply 1 mm thick mortar under each tile or ceramic in order to cover the defects on the application surface. When applying tiles or ceramics in place, the tiles or ceramics are floated in the mortar to ensure that the 1014 Performence is fully in contact. Application is completed by leaving the recommended joint gap according to the appropriate tile or ceramic size. Termatect Joint Fillings should be used to fill the left joint gaps. Joints can be applied after approximately 24 hours.